ODOT-S4E2: 4 Serial Modbus RTU/ASCII ad Modbus TCP converter

Product Feature:

♦ subsidia protocollo conversionis inter Modbus-RTU et Modbus-TCP

♦ sustinet nexum clients of5 TCP eodem tempore

♦ ODOT-S2E2 subsidia 2*RS485

♦ ODOT-S4E2 subsidia wiring ex RS485/RS232/RS422

♦ Quisque Vide portum sustinet Modbus domini servi

♦ ODOT-S2E2:2 Vide Modbus-RTU/ASCII ad Modbus-TCP Servo portae

♦ ODOT-S4E2:4 Vide Modbus-RTU/ASCII ad Modbus-TCP Servo portae

♦ sustinet unum clavem reset

♦ Porta modus operandi: Transparens transmissio, inscriptio mapping


Product Detail

Product Tags

Product Download

Product Details

ODOT-S2E2/S4E2 porta est Modbus-RTU/ASCII ad Modbus-TCP protocollum convertentis.Hoc productum potest coniungere Modbus fabrica ad PLC et computatrum magistrum, qui functiones Modbus-TCP sustinet.Connexionem 5TCPclients simul sustinet.Et productum aluminium mixturae testam adhibet cum firmo consilio et institutionem saxum saxum sustinet.Omnes serial signum dant constructum-in solitudine photoelectrica.

ODOT-S4E2

Technical Parameters

Mechanica Property

Testa: Aluminium alloy

Pondus: 305g(ODOT-S2E2)New

Dimensio: 27.5* 110* 110mm

Temperature: -40 〜85°C

Repono Temperature: -55 〜125°C

Relativum Umor: 5 〜95% (nulla condensatio)

Input Voltage: 9〜36 VDC

Wiring: 3.81mm obturaculum cochleae terminalis

Potentia:

Max.l00mA@24V(ODOT-S2E2)

Max.200mA@24V(ODOT-S4E2)

Modbus Serial

Port Number: 2(ODOT-S2E2) 4(ODOT-S4E2)

Portus Protocol: Modbus-RTU/ASCII

Serial Standard: 2* RS485(ODOT-S2E2) VEL RS485/RS232/RS422(ODOT-S4E2)

Wiring: 3.81mm obturaculum cochleae terminalis

ESD Praesidium: ± 16KV

Rs485 Terminal Resistentia: Externi 120Ω

Data Bits: 7,8

Subsisto Bits: 1,2

Reprehendo digiti: Nemo, etiam, impar

Baud Rate: 1200~115200 bps

In onere: Quisque Vide portum theoretice 31 PCs machinarum suspendere potest (Rs485/RS422)

Aer Interface

Protocollum: Modbus-TCP server

Portuum Number: 2 PCs (sustinet mutandi munus)

Communicatio Rate: l0M/l00Mbps, adaptiva sui ipsius

Connector: RJ45

 

Pelagus Technical Parametri

Modus Network operandi: Transparens transmissio et inscriptio destinata sunt ad libitum, Modbus TCP protocol

Protocollum retis: AERNET, ARP, IP, TCP, ICMP

TCP Connection: Max.5 at pede

Servus adstipulatur: Max.62pcs (nullam nullam)

Mapping Modus Protocol Function Code: 0x01,0x02,0x03,0x04,0x05,0x06,0x0F, 0x10

Modbus Data at Area:

0xxxx area (coil): 8192 Bit

Ixxxx area (discreta input): 8192 Bit

3xxxx area (input register): 2048 Verbum

4xxxx area (recensum tenens): 2048 Verbum

3xxxx area (system diagnosis area): 263 Word

 

Informationes iussis

ODOT-S2E2: 2 Portus Modbus RTU/ASCII ad Modbus TCP Servo Porta, Serial subsidia RS485,9-36V DC, -40~85°C

ODOT-S4E2: 4 Portus Modbus RTU/ASCII ad Modbus TCP Servo Porta, Serial subsidia RS485,9~36V DC, -40~85°C