CT-5321: Modbus Serial Portus Module officinas et artifices |ODOT

CT-5321: Modbus Serial Port Module

Product Feature:

CT-5321 Modbus Serial Port Module

1 Module Description

Modbus Vide portum moduli sustinet canalem 1 RS485/RS232 / RS422 (libitum), Modbus RTU/ASCII protocollum sustinet, ac dominum, servum ac liberum modum transmissionis perspicuae sustinet.

Vide Modulum CT-5321 applicari modulis adaptatoriis, ut Modbus in alia protocolla convertere posset ut Modbus TCP, Profinet, EtherCAT, EtherNet/IP, etc. Cum modulus adhibetur, Vide parametri portum ac Modbus instructiones configurari in IO Mando software.

machinae cum RS485/RS232/RS422 interfaciei, quibus modbus-RTU/ASCII fulciuntur, applicari possunt cum CT-5321 ad cognoscendam connexionem cum calculis superioribus PLC vel superioribus.CT-5321 applicari possent cum machinis ut: PLC, DCS, remotis IO, VFD, motoriis initium praesidii fabrica, intelligens alta et humilis voltage electrica apparatus, potentia mensurae fabrica, intellectus campus mensurae instrumentum et instrumenta, etc.


Product Detail

Demo Video

Product Tags

Product Download

Product Details

CT-5321 Modbus Serial Port Module

Technical Parameters

General parametri

Potestas Max.500mA@5.0Vdc
Separatio I/O bus internis: opto-duobus solitudo (3KVrms)
Ager Power Nominal:24Vdc, Range:20-28Vdc
Wiring I/O Wiring Max.1.5mm²(AWG 16)
Adscendens Type 35mmDIN-Rail
Magnitudo 115*14*75mm
Pondus 65g

Environment Specification

Operational
Temperature
-40~85℃
Operational
Umor
5%~ 95% RH (No Condensation)
Praesidium Classis IP20

Vide Parameters Portus

Nota: M parametros validos modi magistri significat, S validum repraesentatparametri modus servilis, et F parametri liberae perspicui validum repraesentattradendi modus

M/S/F:Channel
Numerus
1Channel
M/S/F:Interface RS485/RS232/RS422
M/S:Protocol Modbus RTU/ASCII
M/S/F:Opus
Modus
Modbus Magister, Servus, Transmissio Transparens
M/S/F:Baud Rate 300bps-500Kbps
M/S/F:Data Bit Bit 7, Bit 8
M/S/F:Parity
CATASTALTICUS
None, Odd, Even
M/S/F:Desine Bit Bit1, Bit2
M/S/F:
Mores Intervallum
1.5t-200t
F: Byte Order
Conversio
Prohibe, Admitte
M/F:Response
Timeout
nativus default: 1000
M/F: Polling
Timeout
nativus default: 100
M: Read Data
Processing Modus
Ultimum valorem initus habe, initus valorem purga
M: Data
Output Modus
Suffragium, res CT (notitia mutationes)
M: Module
Imperium activare
Prohibe, Admitte
M: Module
Imperium Modus
Level felis (continue validum), ore ortu felis (uno*
validum)
M: Power on
Event Output
Prohibe, Admitte
S: Servus ID nativus defalta: 1
S: Responsio
Tempus
nativus default: 50