1. OMNIBUS Type
2. index rei publicae
3. N/A
4. Wiring Terminatio et idem
5. Internum Bus
6. Field Power
7. Fibula
8. Grounding Resilient Sheet
9 certa Wiring iungite
General parametri
Power: Max.50mA@5.0Vdc
Solitudo: I/O bus internis: magnetica solitudo (2.5KVrms)
Field Power: not used
Wiring: I/O Wiring: Max.1.5mm²(AWG 16)
Adscendens Type: 35mmDIN-Rail
Size: 115*14*75mm
Pondus: 65g
Environment Specification
Temperature operational: -40~85℃
Humor operational: 5%~ 95% RH (No Condensation)
Praesidium Classis: IP20
Parameter input
Channel Number: 4 Channels
DUXERIT Testimonium: 4 Input DUXERIT Indicatores
Sensor Type: J / K/ E / T / S / R / B / N genus thermocouples
Acquisitionem Accuracy:
±0.3% Full Scale, @25℃
±0.5% Scala plena, @-40~85℃
Sampling Rate Single Channel: 50Hz (Max.)
Mensuratio dolor
J Type -210~1200℃
K Type -270~1370℃
E Typus -270~1000℃
T Type -270~400℃
S Type -50~1760℃
R Type -50~1760℃
B Type 0~1820℃
N Type -270~1300℃
Data Format 16-bit Signatus Integer (Integer)